Print Formatting Tokens
57
7.0
Print Formatting
The
480
provides multiple print formats, GFMT, NFMT, ACCFMT and SPFMT, that determine the format of the
printed output when the
key is pressed. If a tare has been entered or acquired, NFMT is used; otherwise,
GFMT is used.
Each print format can be customized to include up to 300 characters of information, such as company name and
address, on printed tickets. Use the indicator front panel (PFORMT menu) to customize the print formats.
Display will only show capital letters. Press the down arrow to view the ASCII character decimal value on the
second menu level. Refer to Table 9-6 on page 72 and Table 9-7 on page 73 to view the ASCII character
charts.
7.1
Print Formatting Tokens
Table 7-1 lists tokens that can be used to configure the print formats. Tokens included in the format strings must be
enclosed between < and > delimiters. Any characters outside of the delimiters are printed as text on the ticket. Text
characters can include any ASCII character that can be printed by the output device.
Token
Description
<G>
Gross weight in displayed units.
<G2>
Gross weight in non-displayed units. ***
<N>
Net weight in displayed units.
<N2>
Net weight in non-displayed units. ***
<T>
Tare weight in displayed units.
<T2>
Tare weight in non-displayed units. ***
<A>
Accumulated weight in displayed units.
<AC>
Number of accumulator events (5 digit counter).
<AD>
Date of last accumulator event.
<AT>
Time of last accumulator event.
<UID>
Unit ID number
<CN>
Consecutive number
<NL
nn>
New line (
nn
= number of termination (<CR/LF> or <CR>) characters).*
<SP
nn>
Space (
nn
= number of spaces).*
<SU>
Toggle weight data format (formatted/unformatted). ** ***
<TI>
Time
<DA>
Date (prints 4 digit year)
<TD>
Time & Date
<SCV>
Setpoint captured value.
<STV>
Setpoint target value.
<SPM>
Setpoint mode (Net or Gross)
<SN>
Setpoint number
Gross, net, and tare weights are 9 digits in length, including sign (10 digits with decimal point)
followed by a space and a two-digit units identifier. Total field length with units identifier is 12
(or 13) characters.
UID and consecutive number (CN) fields are 6 characters in length.
* If
nn
is not specified, 1 is assumed. Value must be in the range 1–99.
** After receiving an SU command, the indicator sends unformatted data until the next SU
command is received. Unformatted data omits decimal points, and leading and trailing
characters.
*** Not available if regulatory mode is set to OIML.
Table 7-1. Print Format Tokens