REFUdrive 500 RD51
Basic parameterization
5-9
DOK-RD500*-RD51*******-IB01-EN-P
Parameter
No.:
Name
Description / Explanation
selectable options
Factory setting
min ... max values
Pass-
word
62 = IT motp. slower
:
70 = O no function
71 = O ready to switch on (O=output)
72 = O ST ready swotch on (ST=status)
73 = O ready for operating
74 = O ST ready for operating
75 = O operating
76 = O not fault
77 = O switch on inhibit
78 = O not alarm
79 = O motor rotating 1 (on & ((t <x.x sec) or (i>x.xx %)))
80 = O motor rotating 2 (on & (fist > fmin) & (i > x.xx %))
81 = O direction right
82 = O current limitting
83 = O not mot. alarmtemp.
84 = O not mot.overtemp. (Fault: motor temperature)
85 = O RFG up
86 = O RFG down
87 = O RFG reached
88 = O setpoint reached
89 = O setpoint in tolerance
90 = O fmin limiting
91 = O fmax limiting
92 = O selection TEST
93 = O ctrl. main contact
0756
time timer
Supplementary parameter for “A motor rotating 1“.
1.0 sec
1
Timer for timer element
0.0 ... 650.0 sec
0435.00
Fix value Dxxxx
Supplementary parameter for “A motor rotating 1“.
0.00 %
1
Current threshold (100% = IratedMotor)
-199.99 ... 199.99 %
0757
hysteresis x:xs
Supplementary paramete for “A motor rotating 1“.
1.00 %
1
Hysteresis for current
0.00 ... 100.00 %
0759.00
hysteresis x:xs
Supplementary parameter for “A motor rotating 2“.
1.00 %
1
Hysteresis for frequency
0.00 ... 100.00 %
0759.01
hysteresis x:xs
Supplementary parameter for “A motor rotating 2“.
1.00 %
1
Hysteresis for current
0.00 ... 100.00 %
0435.01
Fixvalue for Dxxxx
Supplementary parameter for “motor rotating 2“.
0.00 %
1
Current threshold (100% = IratedMotor)
-199.99 ... 199.99 %
0760
fixvalue xs input
Supplementary parameter for „setpoint reached“ and
„setpoint in tolerance“.
2.00 %
1
Tolerance value for frequency
0.10 ... 100.00 %
0761
hysteresis x:xs
Supplementary parameter for „setpoint reached“ and
„setpoint in tolerance“.
1.00 %
1
Hysteresis for frequency
0.00 ... 90.00 %
0762
time timer
Supplementary parameter for „setpoint in tolerance“.
1.0 sec
2
Time value for timer element
0.0 ... 650.0 sec
0876
dig. in-, output2
I no function
1
As for parameter 0875
0...93
0877
dig. in-, output3
I no function
1
As for parameter 0875
0...93
0878
digital input4
I no function
1
As for parameter 0875, from value 0 to 69.
0...62
0879
digital input5
I no function
1
As for parameter 0875, from value 0 to 69.
0...62
0880
digital input8
I no function
1
As for parameter 0875, from value 0 to 69.
0...62