1-4
Description
REFUdrive 500 RD51
DOK-RD500*-RD51*******-IB01-EN-P
Technical Data for pulse frequency f
p
= 4 kHz
RD51
045
055
075
090
110
132
160
200
315
400
Motor output
3
[kW]
45
55
75
90
110
132
160
200
315
400
Line supply voltage 3 AC 400 V (±15%)
Output frequency
[Hz]
0 - 250
0 - 150
Rated current
[A]
82
99
135
165
195
230
290
350
540
680
Peak current for
t=60 s [A]
107
129
176
215
253
299
377
455
702
884
t=1 s
[A]
139
168
230
281
331
391
493
595
918
1156
t=0.5 s [A]
164
198
270
330
390
-
-
-
-
-
Rated output S
N
[kVA]
54
65
89
109
128
151
191
230
355
448
Peak output for t=60s
[kVA]
70
85
116
142
167
197
248
299
462
582
Line supply voltage 3 AC 460 V (±15%)
Output frequency
[Hz]
0 - 250
0 - 150
Rated current
[A]
72
86
120
139
178
200
252
305
470
591
Peak current for
t=60 s [A]
107
129
176
215
254
299
377
455
702
884
t=1 s
[A]
139
168
230
281
332
391
493
595
918
1156
t=0.5 s [A]
164
198
270
330
390
-
-
-
-
-
Rated output S
N
[kVA]
54
65
89
109
128
151
191
230
355
448
Peak output for t=60s
[kVA]
70
85
116
142
167
197
248
299
462
582
Line supply voltage 3 AC 500 V (+10% / -15%)
Output frequency
[Hz]
0 - 250
0 - 150
Rated current
[A]
66
80
108
130
160
190
240
280
432
550
Peak current for
t=60 s [A]
86
104
140
169
208
247
312
364
562
715
t=1 s
[A]
112
136
184
221
272
323
408
476
734
935
t=0.5 s [A]
132
160
216
260
320
--
--
--
--
--
Rated output S
N
[kVA]
54
66
89
107
132
156
197
230
355
452
Peak output for t=60s
[kVA]
71
86
115
139
171
203
257
299
462
588
Ambient conditions, radio interference suppression level, noise immunity
Environmental class
3K3 according to DIN IEC 721-3-3 (ambient temperature 0-40 °C)
Cooling airflow requirement
[m³/s]
0.2
0.4
0.4
0.6
0.4
0.4
0.4
0.6
0.8
1.2
Radio interference suppression level/ noise immunity A 1 according to EN 55011 / EN 61800-3
Mechanical design
Size classes
C
D
D
E
E
G
G
G
H
H
Degree of protection
IP 20 according to EN 60529 (without terminal connections)
Weight of the drive converter for cooling type
Forced ventilation
[kg]
33
50
50
80
80
--
--
--
--
--
Liquid cooling
[kg]
25
37
37
60
60
180
180
180
358
358
Heat conducting plate
[kg]
--
--
--
--
--
--
--
--
--
--
Brake resistor
Continuous braking power
4
[kW]
0.4
0.6
0.6
0.8
1.2
2
2
2.5
4
5
3
Maximum permissible motor output referred to a 4-pole standard induc-
tion motor.
4
When the braking resistors are mounted in the air flow.
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01