1-6
Description
REFUdrive 500 RD51
DOK-RD500*-RD51*******-IB01-EN-P
Technical Data for pulse frequency f
p
= 8 kHz (* for 110 kW f
p
= 6 kHz)
RD51
045
055
075
090
110*
132
160
200
315
400
Motor output
7
[kW]
37
45
55
75
90
110
132
160
250
315
Line supply voltage 3 AC 400 V (±15%)
Output frequency
[Hz]
0 - 500
0 - 250
Rated current
[A]
68
82
99
135
165
195
230
280
400
540
Peak current for
t=60 s [A]
88
107
129
176
215
254
299
364
520
702
t=1 s
[A]
116
139
168
230
280
332
391
476
680
918
t=0.5 s [A]
136
164
198
270
330
--
--
--
--
--
Rated output S
N
[kVA]
45
54
65
89
109
128
151
184
263
355
Peak output for t=60s
[kVA]
58
70
85
116
142
166
197
240
342
462
Line supply voltage 3 AC 460 V (±15%)
Output frequency
[Hz]
0 - 500
0 - 250
Rated current
[A]
60
72
86
118
132
170
200
243
348
470
Peak current for
t=60 s [A]
88
107
129
176
215
254
299
364
520
702
t=1 s
[A]
116
139
168
230
280
332
391
476
680
918
t=0.5 s [A]
136
164
198
270
330
--
--
--
--
--
Rated output S
N
[kVA]
45
54
65
89
109
128
151
184
263
355
Peak output for t=60s
[kVA]
58
70
85
116
142
166
197
240
342
462
Line supply voltage 3 AC 500 V (+10% / -15%)
Output frequency
[Hz]
0 - 500
0 - 250
Rated current
[A]
55
66
80
108
130
160
190
240
345
432
Peak current for
t=60 s [A]
72
86
104
140
169
208
247
312
449
562
t=1 s
[A]
94
112
136
184
221
272
323
408
587
734
t=0.5 s [A]
110
132
160
216
260
--
--
--
--
--
Rated output S
N
[kVA]
45
54
66
89
107
132
156
197
284
355
Peak output for t=60s
[kVA]
59
71
86
115
139
171
203
257
369
462
Ambient conditions, radio interference suppression level, noise immunity
Environmental class
3K3 according to DIN IEC 721-3-3 (ambient temperature 0-40 °C)
Cooling airflow requirement
[m³/s]
0.2
0.4
0.4
0.6
0.4
0.4
0.4
0.6
0.8
1.2
Radio interference suppression level/ noise immunity A 1 according to EN 55011 / EN 61800-3
Mechanical design
Size classes
C
D
D
E
E
G
G
G
H
H
Degree of protection
IP 20 according to EN 60529 (without terminal connections)
Weight of the drive converter for cooling type
Forced ventilation
[kg]
33
50
50
80
80
--
--
--
--
--
Liquid cooling
[kg]
25
37
37
60
60
180
180
180
358
358
Heat conducting plate
[kg]
--
--
--
--
--
--
--
--
--
--
Brake resistor
Continuous braking power
8
[kW]
0.4
0.6
0.6
0.8
1,2
2
2
2.5
4
5
7
Maximum permissible motor output referred to a 4-pole standard induc-
tion motor.
8
When the braking resistors are mounted in the air flow.
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01