REFUdrive 500 RD51
Electrical installation
3-11
DOK-RD500*-RD51*******-IB01-EN-P
Description of the power terminals, sizes G and H
Terminal Comment
X1
Supply connection
PE
Protective conductor connection; for size G = terminal rail with cable terminal
for size H = terminal rail with M16 studs
U1
V1
W1
Supply connection, 3 phases L1, L2, L3
Permissible line supply voltage, refer to the rating plate
121
122
Checkback signal contact (NC contact) from the main contactor
X2
Motor connection, DC link, line supply isolation
C
DC link terminal L+
D
DC link terminal L-
F
Internal brake resistor in the heat exchanger is connected between C and F
1 (L/P)
2 (0V
AC)
Heat exchanger fan connection
U2
V2
W2
Motor connection U, V, W
for size G = cable terminal
for size H = M16 studs
151
152
153
154
Function: Isolating from the line supply
In operation, terminals 151 - 152 and 153 - 154 must remain closed; when they are opened, the
unit is isolated from the line supply.
If isolation from the line supply is required, both terminals must be opened, in order to avoid er-
roneous function when a ground occurs.
When the terminals are opened, the auxiliary circuits are in a no-voltage condition, and the
open-loop and closed-loop control does not function.
155
156
157
158
Function: Isolating from the line supply
In operation, terminals 155 - 156 and 157 - 158 must remain closed; when they are opened, the
unit is isolated from the line supply.
If isolation from the line supply is required, both terminals must be opened, in order to avoid er-
roneous function when a ground occurs.
When the terminals are opened, the auxiliary circuits are in a no-voltage condition, and the
open-loop and closed-loop control does not function.
X5
Control voltages for the line supply filter
1
3
5
Control voltage supply, 3 x AC
7
9
11
Control for pre-charging- and
main contactor with checkback
signal (NO contact) for the main
contactor.
The customer must establish the connection from the line
filter to the drive converter after mounting. Insert the cable
assembly with connector (coming from the line filter) into X5.