installation
Grandview
®
G600C Gas Fireplace
|
81
Installing the Optional Fan (Part #761-979)
10.23.20
920-193a
3
G600C
OPTIONAL FAN INSTALLATION (Part #761-974)
920-133
06.24.19
1
FAN INSTALLATION
1. The fan may be installed after the unit has been installed and fi nished.
Ensure the unit is turned off and has cooled to room temperature.
2. Remove the screen and glass door (see unit manual for details).
3. Remove any media already installed (logs, glass, etc.) set aside.
4. Remove the log grate.
5. Remove the burner.
6. Remove the fi rebox fl oor panel (brick or enamel).
7. Remove screen from light assembly.
Important:
120 Volt AC power is needed for the blower. The receptacle
box will be installed on the left hand side of the unit and will need to
be wired by a qualifi ed electrician prior to fan assembly being installed.
The neutral (wider) slot of the polarized receptacle should be at the top.
.
Unit must be grounded at all times. Do not cut the ground terminal
off under any circumstances.
1. Shut the power off .
2. Remove the safety screen and glass door (see unit manual for details).
Diagram 1- panel removal
Diagram 3- fan wires
Diagram 2- fan install
4. Install fan assembly onto pins on unit fl oor.
Note: Diagram below shows fan bracket only.
5. Fold access panel cover down and secure with 2 screws.
6. Connect red + black wires to fan assembly.
8. Connect fan ground cable to ground lug (located in lower right corner
of unit). Refer to wiring diagram.
7. Connect red + black fan wires to corresponding red + black wires on
the DFC box as shown.
3. From the back of the unit—remove 2 screws from the fan access panel
(locations shown below). Gently fold panel cover upwards.
FAN INSTALLATION PRIOR TO INSTALLATION
FAN INSTALL AFTER UNIT INSTALLATION
Diagram 4- fan wires
Diagram 5- DFC wires
Diagram 6- ground wires
3. From the back of the unit - remove 4 screws from the fan access
panel (locations shown below).
4. Push fan speed control module towards the front of the unit (this
will later be screwed in place from the front) and attach thermo-
disc cage to bracket on the underside of the firebox.
5. Push power cord and ground wire towards front of unit. Connect
two green ground wires to ground lug, accessed from the front of
the unit. Refer to wiring diagram.
9. Plug power cord into unit electrical outlet.
6. Secure fan speed control module in place with 2 screws.
Important: 120 Volt AC power is needed for the blower. The recep-
tacle box will be installed on the right hand side of the unit and will
need to be wired by a qualified electrician prior to fan assembly
being installed. The neutral (wider) slot of the polarized receptacle
should be at the top.
Unit must be grounded at all times. Do not cut the ground
terminal off under any circumstances.
1. Shut the power off.
2. Remove the safety screen, glass door and bottom cover panel
(see unit manual for details).
7. Install fan assembly onto pins on unit floor.
8. Secure fan access panel back onto the unit with 4 screws.
Summary of Contents for Grandview G600C
Page 100: ...100 Grandview G600C Gas Fireplace warranty ...
Page 101: ... Grandview G600C Gas Fireplace 101 notes ...
Page 102: ...102 Grandview G600C Gas Fireplace notes ...
Page 103: ......