installation
Grandview
®
G600C Gas Fireplace
|
35
Outside Finish
Installation (Non Cool Wall) - Mantel Clearances
Note: Ensure the paint that is used on the mantel and the facing is high quality or the paint may discolour.
Due to the extreme heat this fireplace emits, the mantel clearances are critical.
Combustible mantel clearances from top of front facing are shown in
the Diagram below.
Mantel Clearances
G600C
A
B
C
D
From Top of Fireplace
30" (762mm)
19-1/2" (495mm)
15-3/4" (400mm)
10-1/2" (267mm)
Combustible
Mantel Clearances
0
5
10
0
Top of
Fireplace
12"
(305 mm)
5"
(127 mm)
17"
(432 mm)
A
B
15
To Floor
Inches
C
D
Non-Combustible Material
Min. 10 1/2" H (267mm)
5
10
20
15
Outside Finish
Installation (Non Cool Wall)—Mantel Leg Clearances
Allowable mantel leg projection
TopView
Side opening
of fireplace
Mantel
Mantel Leg
1-1/2"
4-1/4"
(108mm)
Leg
6-7/8" (175mm)
3
2"
(
8
13 mm)
Overall Fireplace Width (Outside Finish)
3”
**The non combustible board supplied with the appliance is 13" (330 mm) high. This may be cut to size if desired.