installation
Grandview
®
G600C Gas Fireplace
|
63
LP CONVERSION
G600C
2
09.21.20
920-326
1
9) If the conversion is from NG to LPG, the
screw must be re-assembled with the
red o-ring visible (Fig. 5).
LPG Configuration
Red o-ring visible
Fig.5
20)
Re-assemble the black protection
cap (Fig. 6).
Fig. 6
WARNING!
Check that the pilot and main burner
injectors are appropriate for the gas
type.
21)
Reverse steps 6 - 1.
Fig.4
Fig.3
16)
Check that the screw is clean and
remove dirt if necessary.
17)
Flip the screw (Fig. 3).
18) Using the Allen
wrench as shown in
Fig.4, rotate the screw
clockwise until snug.
Do not overtighten.
WARNING!
Do not over tighten the screw.
Recommended to
grip the wrench by the short side.
22) Attach the label "This unit has been
converted to LPG" near or on top of the
serial # decal.
23) Replace yellow "NG" label with red
"LPG" label.
24) Reinstall burner assembly.
25) Adjust aeration accordingly—see
manual for details. Aeration must be set
to 3/16" for LP.
26) Reverse steps 4–1.
27) Check for gas leaks.
28) Check inlet and outlet pressures.
29) Check operation of flame control.
Summary of Contents for Grandview G600C
Page 100: ...100 Grandview G600C Gas Fireplace warranty ...
Page 101: ... Grandview G600C Gas Fireplace 101 notes ...
Page 102: ...102 Grandview G600C Gas Fireplace notes ...