installation
Grandview
®
G600C Gas Fireplace
|
77
Aeration Adjustment
The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a
more yellow flame.
Minimum Air Shutter Opening:
NG 1/8" (3 mm)
LP 3/16" (5 mm)
CAUTION:
Carbon will be produced if air shutter is tightly closed.
Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty.
Pull lever forward to open - push back to close.
Air shutter lever - located in the center of the unit under the firebox
Electrical Access and Installation
The electrical access panel is on the right side of the unit (when facing the
front of unit).
1.
Remove panel by removing three (3) screws.
2.
Remove center knockout to run cable through the access panel and
install supplied clamp.
3.
Attach wires from cable to supplied white receptacle and secure to
gang box. Screw the receptacle cover to gang box. Reinstall panel by
removing three (3) screws.
4.
The 120 volt power cord supplied with appliance will need to be plugged
into the receptacle only once the install is complete.
Summary of Contents for Grandview G600C
Page 100: ...100 Grandview G600C Gas Fireplace warranty ...
Page 101: ... Grandview G600C Gas Fireplace 101 notes ...
Page 102: ...102 Grandview G600C Gas Fireplace notes ...
Page 103: ......