installation
Grandview
®
G600C Gas Fireplace
|
25
Cool Wall Installation—Framing
Framing Dimensions
Description
Cool Wall
M
Framing Width
33-1/2" (85mm)
N*
Framing Height
40" (1016mm)
O
Framing Depth
15" (381mm)
P
Corner Facing Wall Width
37-1/4" (946mm)
Q
Corner Facing Wall Width
52-1/2" (1334mm)
R
Framed Chase Ceiling
Enclosure
74-1/2" (1892mm)
S (Rear Vent)
Vent Centerline Height - Rear
25" (635mm)
S (Top Vent)
Vent Centerline Height - Top
39-1/2" (1003mm)
T
Gas Connection Height
1-7/8" (48mm)
U
Gas Connection Inset
8-3/8" (213mm)
V
Gas Connection Width
3-1/2" (89mm)
W
Clearance to Corner of Unit
1/2" (13mm)
* Important: Framing height requires consideration of the hearth height. Dimension N = N + the thickness of the installed hearth.
P
R
M
N
O
S
S
U
T
V
Combustible header
Top Vent
Rear Vent
W
Q
Note: The 2 standoffs at the rear of the appliance may be removed as these are not required in this application. Ensure
that any screws that are removed are reinstalled. The 2 standoffs can be recycled/discarded.