149
ESPLXD-ET Controller
Set FloZone
TM
Rates
b
g
Turn the controller dial to Module Programming.
A
The Smart Module PGM screen appears with Flow Smart Module
selected; press Next.
B
The Flow Smart Module PGM screen appears with Set Flow Rates
selected; press Next.
1
2
C
The Set Flow Rates screen appears. Press the Down Arrow button
to select Set FloZone Rates; then press Next.
D
The FloZone Flow Rates screen appears. Press + and – (buttons 1
and 2) to select the desired FloZone number; then press - (button
4).
3
4
E
Press + and – (buttons 3 and 4) to enter the desired Flow Rate for
that FloZone. Press – (buttons 2 and 4) to navigate between the
FloZone and Flow Rate fields.
b
l
Press and HOLD buttons to accelerate settings for GPM.
b
b
NOTE:
Maximum FloZone flow rates are used only by FloManager.
FloWatch is unaffected by user-entered FloZone flow rates.
5
b
e
Repeat this process to manually set up Flow Rates for additional
FloZones as desired.
After FloManager is enabled and station and/or FloZone flow rates
are entered, FloManager works automatically in the background to
run stations based on available hydraulic capacity
b
b
NOTE:
FloManager can be used with or without flow sensing
hardware. If flow sensors are not present it will rely on manually
entered information; if flow sensors are present it will rely on
Learned Flow information, which is typically more accurate.