Configuring the Built–in Gatekeeper
4-22
!
To display the Neighbor Gatekeepers Table
•
In the
Application Parameters
screen click
Neighbor Gatekeepers
. The
Neighbor
Gatekeepers Table
is displayed.
Figure 4-9 –Neighbor Gatekeepers Table screen
The
Neighbor Gatekeepers
Table
screen displays the following parameters and settings:
Number of Entries
— Displays the number of neighbors defined for the Gatekeeper. When
you add or delete a neighbor, this counter updates automatically.
Max Entries
— Displays the maximum number of neighbors that can be registered with the
current Gatekeeper. Currently, the maximum number is 50.
Description
— This is the description of the Neighbor Gatekeeper. To enable Proxy
support, the word "proxy" must be entered as the description, see
Gatekeeper Proxy Support
for more information.
Neighbor IP
— The IP address of this Neighbor Gatekeeper. This field is mandatory.
Port
— The port number of this Neighbor Gatekeeper.
Summary of Contents for MCU-323
Page 1: ...P N 61288 00001 Rev C MCU 323 Multipoint Conferencing Unit User Guide...
Page 8: ...Table of Contents vi Glossary Index...
Page 14: ......
Page 30: ......
Page 36: ......
Page 44: ......
Page 46: ......
Page 84: ......
Page 92: ......
Page 120: ......
Page 122: ......
Page 138: ......
Page 140: ......
Page 144: ......
Page 146: ......
Page 152: ......
Page 155: ...A Safety Considerations...
Page 156: ......
Page 158: ......
Page 159: ...B Cable Connectors...
Page 160: ......
Page 163: ...C Uploading Files to the MCU 323...
Page 164: ......
Page 166: ...Uploading Files to the MCU 323 C 2 Figure C 1 Software Upload Utility screen...
Page 168: ......
Page 169: ...D Technical Specifications...
Page 170: ......
Page 172: ......
Page 180: ......