Scalar DLC Reference Guide
301
ROBAR Coordinates
For all physical positions in the system, the Scalar DLC software provides a signification coordinate. With
the help of this coordinate, the Scalar DLC can compute the physical position. These are LSCI coordinates
(the Scalar DLC database contains a coordinate decoder and uses the LSCI coordinate system as well as
SCSI coordinates, and others). Refer to
Element Addressing
on page 260.
Additionally, for the Insert/Eject unit, Drives, Jukebox, and Problem box, the ROBAR interface uses special
coordinates.
Table 45
ROBAR Coordinates
Area
Description
Example
Storage area
typical LSCI coordinate - device, column, row, position
01010101 (device 1, column
1, row 1, position 1)
Insert area
coordinate starts with 0001 followed by row and
position
00010510 (row 5, slot 10)
Eject area
coordinate starts with 0002 followed by row and
position
00020608 (row 6, slot 08)
Foreign
Mount area
coordinate starts with 0003 followed by row and
position
00030701 (row 7, slot 01)
Drive/
Jukebox
coordinate starts with 0000 followed by the drive
address/name and 01
00000F01 (drive addr. 0F)
0000ZQ01 (drive name ZQ)
Problem box
coordinate starts with 000000 followed by number of
the problem box
000000001 (problem box 1)
Summary of Contents for Scalar Distributed Library Controller 2.7
Page 1: ...ReferenceGuide Scalar DistributedLibraryController 2 7 ...
Page 8: ...viii Table of Contents ...
Page 16: ...xiv Figures ...
Page 48: ...30 Configuration ...
Page 94: ...76 Management GUI ...
Page 206: ...188 Configuration Tab ...
Page 216: ...198 Events Tab ...
Page 272: ...254 Tools and Utilities ...
Page 294: ...276 Application Notes ...
Page 302: ...284 DAS Guide ...
Page 312: ...294 SCSI Guide ...
Page 320: ...302 ROBAR Guide ...
Page 324: ...306 Index ...