54
133
R/W
How long will the error be
displayed and/or the alarm
output activated, in [ms].
Depending on error type and
setting, measurement will
continue
0, 1, …. 60 000
if trigger
function is
active, message
will display at
least until the
next successful
measurement
occurs
0
144
W
Teach Register
Bit 0 = Set Q1 ON
Bit 1 = Set Q1 OFF
Bit 2 = Set Q2 ON
Bit 3 = Set Q2 OFF
Bit 4 = Set QA 0/4 mA
Bit 5 = Set QA 20 mA
Bit 6 = Set Offset
Bit 7 = Set Q3 ON
Bit 8 = Set Q3 OFF
Only for Teach
0
160
R/W Activate measurement mode
0 = Trigger
mode
1 = Continuous
measurement
1
161
R/W Signal quality
By writing this,
quality
measurement is
started. Can
then be read
through the
read function.
Value = 0 –
unsuccessful
measurement.
Values between
1 bad & 8900
very good
Switch-off the
Laser after
measurement,
(Reg .163).
Measuring
mode needs to
be restarted,
Reg. 160.
162
W
Laser off
164
W
Laser on
250
R/W
Q1 - lower switch point MSW
in [mm]
0,1, … 100 000
32-Bit
50
251
Q1 – lower switch point LSW
"