42
running simultaneously and you want to find the next equipment after the first stop, you will need to
enter the subsequent address and start searching again.
Example: A sensor has been detected through the search function at address 5; you want to continue
searching; enter figure 6 in the box
Current Address
and start searching again.
Repeat searching as many times as necessary to detect all sensors or the one you are looking for.
Language
In the software you can switch from German to English language.
Activate onscreen keyboard
If you are using a device with touchscreen, you can activate the software onscreen keyboard.
Polling interval (ms)
This information defines how frequently software asks the sensor to provide measurement data, and
has an impact on refreshing in operating display, and on data recording in protocol file. Values
between 100 and 1000 ms can be set.
Sensor Information
The
settings
mode displays following information relevant to the sensor:
Manufacturer
Type/Indication
Article no.
Measuring range
Software version
Serial number
Internal temperature
(temp. inside the
sensor)
Connect Proxitron Laser Sensor with software
Information is read out any time you click on
Connect
.