4.2.3.5
"Software Update" menu
This page is used to view or modify the parameters for a software update and to trigger the
update.
Figure 4-19
"Software Update" web page
During a firmware update, the current status is shown on the MMS display:
03 - Downloading firmware via the network.
04 - Saving the firmware in the MMS Flash memory.
05 - The new firmware has been saved successfully.
Display goes out.
bo - Device is booting and loading new firmware in the RAM.
Following a firmware update, a reset is executed
automatically
to activate the new
firmware.
Please make sure that the "TFTP Server" service program is activated in the Factory
Manager toolbar.
You can monitor the download in the Factory Manager message
window (25%, 50%, 75%, 100%). Always wait until all the LEDs light up after
approximately two minutes and the device is available again after booting.
It is not ensured that all existing configuration data will be retained after a firmware
update/downgrade. Therefore, please check the configuration settings or return the
device to the settings default upon delivery.
NOTE:
A voltage failure during a firmware update results in the destruction of the firmware
on the MMS/MCS. An update via XMODEM is required, see "Starting with faulty software
(firmware)" on page 4-127.