The Modular Managed Switch System (MMS) and the Managed Compact Switch (MCS)
6874_en_16
PHOENIX CONTACT
1-7
1.2.3
Firmware functions and the required hardware (MMS)
1.2.4
Device view (MMS)
1.2.4.1
Front view of the head station
Figure 1-3
Front view of the head station
–
Diagnostic/status indicators
Important information is displayed directly on the device. Each port has two LEDs. The
left-hand LED always indicates the "LINK", while the right-hand LED display is set with
the function switch.
–
Function switch for LEDs
The MODE function switch can be used to specify which information is displayed by the
second port-specific LED. The three LEDs above the switch indicate the selected
mode. This information is then displayed by all port-specific LEDs (see also example
on page 1-13).
–
Connection for extension module (FL MXT)
Connect the first of a maximum of two extension modules here.
Table 1-1
Functions and the required hardware
Function
Required hardware for the
head station
Required hardware for the
extension modules
Standard switch
functions
Hardware Version
≥
3
(includes system bus Version 4.1)
Hardware Version
≥
2
(includes system bus Version 3.1)
Memory module
support
Hardware Version
≥
4
(includes system bus Version 4.2)
Hardware Version
≥
2
(includes system bus Version 3.1)
PoE module sup-
port
Hardware Version
≥
6
(includes system bus Version 5.0)
Hardware Version
≥
4
(includes system bus Version 4.0)
POF-SCRJ mod-
ule support
Hardware Version
≥
6
(includes system bus Version 5.0)
Hardware Version
≥
4
(includes system bus Version 4.0)
MRP module
support
Hardware Version
≥
6
(includes system bus Version 5.0)
Hardware Version
≥
4
(includes system bus Version 4.0)
Slots for interface
modules
Mini-DIN
V.24 (RS-232)
Alarm
contact
Supply voltage
connection
Diagnostic
display
Diagnostic/status
indicators
Reset
button
Function switch
for LEDs
Connection for
extension module
(outgoing system
interface)
67961010
Labeling field
US1
US2
Fail
Reset
MODE
ACT 100
FD
FL SWITCH MM HS
Ord. No. 28 32 32 6
US2
US1 GND
GND
R1
R2
00A0451BDD
MAC
Address
MAC address
LNK MODE
1
2
X1
LNK MODE
1
2
X2
LNK MODE
1
2
X3
LNK MODE
1
2
X4
V.24
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-14178-Phoenix-Contact-2832357-FL-IF-2TX-VS-RJ-D-Media-Module-for-Modular-Switch.aspx