Configuration and diagnostics
6874_en_16
PHOENIX CONTACT
4-35
This menu can be used to set the port-specific configuration settings for Power over
Ethernet.
Properties of PoE mode
–
Up to twelve PoE interface modules with a total of 24 ports can be operated at the same
time in a MMS.
–
Configuration transmission on the interface module is only possible if there is a
connected 48 V supply.
–
The following management functions are available:
- Display error states for each port and communicate via the alarm contact (yes/no)
- Connect/disconnect voltage for each port
- Current limitation for loads classified as Class 1 devices
–
The following diagnostic information is displayed:
- No error
- Surge voltage/undervoltage
- Thermal error
- Overload
- Disconnected load (the current consumption at this port is less than 10 mA, the supply
voltage is disconnected by the PoE module)
- No 48 V supply
- No PoE termination device connected
- No PoE interface module detected at this port
- No hardware support due to the system bus
- Detected class of a connected termination device (Class 0 to Class 4)
- Output voltage and output current
The PoE interface module is supported by firmware Version 4.0 or later. Firmware
Versions < 4.0 treat the module as a standard RJ45 interface module. The module can
operate in PoE mode without management and without support from the firmware and
hardware (system bus). No configuration options or diagnostic data are available.
The use of the PoE interface module requires the application of system bus firmware 5.00
or later in the head station and system bus firmware 4.00 or later in the extension modules.
If this requirement is not met in the head station or in any extension module, then PoE
management is not available in the
entire
system. PoE interface modules can operate
without management and without management support. No configuration options and no
diagnostic data are available, connected termination devices are nevertheless supplied
with power. The system bus firmware is displayed on the "Device Information/General"
web page.
The PoE configuration options are also available if no PoE interface module is inserted. If
a PoE interface module is inserted, the configuration is transmitted to the module after a
few seconds.
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-14178-Phoenix-Contact-2832357-FL-IF-2TX-VS-RJ-D-Media-Module-for-Modular-Switch.aspx