Configuration and diagnostics
6874_en_16
PHOENIX CONTACT
4-23
Load the last stored
configuration
This option can be used to reactivate the last configuration saved in the memory module or
on the device. All modifications made to the configuration since it was last saved are lost.
Figure 4-27
"Load the last stored configuration" web page
"Config. Management/File Transfer" menu
Configuration file transfer
This option can be used to save your device configuration on a PC or to operate the switch
using a saved configuration.
Figure 4-28
"Configuration file transfer" web page
Device replacement
"Config. Management/Memory Module" menu
When a configuration is uploaded from the MMS/MCS to a PC, the last saved version is
transmitted. If you want to transmit the active configuration, first save it again ("Save
current configuration" function).
When a configuration is downloaded from the PC to a MMS/MCS, the new configuration
is only activated once the switch has been reset.
The use of a configuration file does not affect an existing ("old") password.
Configuration using a configuration file is used when replacing devices. To duplicate
devices using a configuration file, observe the following:
–
Create a point-to-point connection between a MMS/MCS and the management
station.
–
Load the configuration file on the MMS/MCS.
–
Reset the MMS/MCS.
–
Adjust the IP parameters.
–
Save the configuration ("Save current configuration" function).
The duplicated switch can now be operated in the network using the adjusted IP
parameters.
RSPSupply - 1-888-532-2706 - www.RSPSupply.com