Messages in Smart mode:
In the event of an error:
Display
Meaning
S1
Exit Smart mode without changes
S2
Reset to default settings
S3
Set PROFINET mode
S4
Set Ethernet/IP mode
Display
Meaning
Remedy
16
The device software (firmware) is
faulty
–
Update the firmware via the serial interface.
17
Firmware transfer via TFTP or
Xmodem failed (display changes
from "03" to "17")
–
Check the physical connection.
–
Establish a point-to-point connection.
–
Make sure that the file (with the specified file name) exists and
is in the correct directory.
–
Check the IP address of the TFTP server.
–
Activate the TFTP server.
–
Repeat the download.
19
File transfer was completed suc-
cessfully, but the file is not a valid
firmware version for the Modular
Managed Switch System
–
Provide a valid firmware version with the previously specified
file name
(Internet:
www.phoenixcontact.com
).
–
Repeat the download.
80
An error has occurred in the firm-
ware
–
Restart the device (power up or reset).
–
Make sure that the IP address is not used more than once in the
same network.
87
More than one parameterization
memory has been plugged in.
–
Remove all but one of the memory modules and execute a
reset.
89
The switch is or was in an excep-
tional situation
–
Restart the device.
–
Check your network for configuration errors, loops, loose
contacts, poor line quality, faulty network interfaces.
–
Make sure that there are no Denial of Service attacks.
Li
Link monitoring has detected at
least one faulty link
–
Check the cables/connectors.
–
In web-based management, check at which port link monitoring
(see page 4-27) is indicating an error.
–
Restore the data connection to this port or deactivate link
monitoring for this port.
–
Check the correct position of the interface module on the head
station or on the extension module.
Cd
The switch is operating as a
PROFINET IO device. The configu-
ration of the switch and the configu-
ration transmitted by the PROFINET
engineering tool are different
–
Set the desired configuration at the switch.
–
Modify the control program so that it contains the existing
switch configuration.