FL SWITCH MM HS
9-2
PHOENIX CONTACT
6874_en_16
Figure 9-1
"Operating Mode" web page
Switching to "Default"
mode
When the switch is reset to "Default" mode from "Profinet" mode, the following settings are
made:
–
LLDP remains active with the values default upon delivery.
–
IP address assignment is set to BootP.
–
The station name for the switch does not change. If no station name has been specified,
the device type is entered.
9.2
Switch as a PROFINET IO device
9.2.1
Configuration in the engineering tool
9.2.1.1
Specifying the bus configuration
The switch can be operated as a PROFINET IO device if it is integrated under a control sys-
tem in the bus configuration in the engineering tool. A GSD file and an FDCML file for inte-
gration can be downloaded at
www.download.phoenixcontact.com
.
It is recommended to save the new configuration after changing operating mode. Please
note that some configuration modifications only take effect after a restart.