10
138
Workshop Manual, TPD 1353E, Issue 3
Peregrine EDi and 1300 Series EDi
10 Fit the remainder of the long setscrews through the metal strips and through the sump to secure them to
the cylinder block. Tighten the setscrews finger tight.
11 Tighten the 22 setscrews to 23 Nm (17 lbf ft) 2,35 kgf m.
12 Fit the drain plug (C4) together with a new sealing washer (C3) and tighten the plug to 68 Nm (50 lbf ft)
7,0 kgf m.
13 Fit the dipstick tube, and fit the dipstick.
14 Fill the lubricating oil sump to the correct level with an approved lubricating oil, see Chapter 5 in the User’s
Handbook.
W061
C
1
2
3
4
5
This document has been printed from SPI². Not for Resale