Installer manual Fleck 3150 NXT/NXT2 - Troubleshooting
Ref. MKT-IM-010 / C - 18.10.2019
155 / 182
• valve address doubled;
• power failure;
• system size: ex. programmed for 4 units, but there are only 2 units;
• units of measure do not correspond between the different valves of the system;
• wrong type of valve programmed.
Cause
Solution
More than one unit programmed with the
same position number.
Program correctly the units using only
once per position number.
Flashing display.
There was a power failure.
Units of measure do not correspond: units
have different units of measure
programmed.
Check and program all units in the system
with the same units of measure.
System size: the number of units in the
system does not correspond to the
number programmed and vice versa.
Check to make sure that system number
and number of units correspond.
10.3
Examples of error displayed
10.3.1
NXT controller
• The unit 2 has been reset;
– Reprogram the unit.
• there is no message from unit 3;
– The number indicate the unit to be checked in the
system.
– Check that communication cables are connected.
– Check the valve address.
• there are more units in the system than programmed
in the lead (#1) unit;
• the programmed values do not match, check the values
programmed in each unit;
– Example: Display format different from one unit to
the other.
– Example: System of 4 units, but only 2 detected or
connected.
• programmed position of units incorrect.
– Lead unit (#1) not programmed.
– 2 or more units are programmed with the same
address.
Summary of Contents for FLECK 3150 NXT
Page 1: ...FLECK 3150 NXT NXT2 INSTALLER MANUAL WATER PURIFICATION ...
Page 139: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 139 182 DC motor ...
Page 144: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 144 182 Ref MKT IM 010 C 18 10 2019 ...
Page 148: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 148 182 Ref MKT IM 010 C 18 10 2019 ...
Page 182: ...www pentairaquaeurope com ...