Installer manual Fleck 3150 NXT/NXT2 - Programming
Ref. MKT-IM-010 / C - 18.10.2019
77 / 182
Generic meter
Info
Only visible if "generic" was selected in flow meter selection.
Set the generic meter.
Info
This parameter has two settings. The first display is to enter the maximum flow rate of
the water meter. The second display is to enter the values for the flow meter (pulses
and volume).
a) Set the maximum flow rate with
,
and
.
b) Press
to validate the selection and advance to the
next parameter.
c) Set the number of liters per pulse(s) with
,
and
.
d) Press
to validate the selection and advance to the
next parameter.
e) Set the number of pulses for the programmed number
of liters with
,
and
.
f) Press
to validate the selection and advance to the
next parameter.
Example: 290 L/min.
Example: 1 liter for
1 pulse.
Example: 5 liter for
1 pulse.
Example: 2 liter for
10 pulses.
6.1.5.21
Parameters saving
Info
When the last parameter is set and the button
pressed, the controller updates the
database based on the new programming. Wait until programming is finished, this may
take a few seconds.