Installer manual Fleck 3150 NXT/NXT2 - Programming
Ref. MKT-IM-010 / C - 18.10.2019
69 / 182
a) Set the valve position with
and
.
ð
Default setting: valve 2 address #2.
b) Press
to validate the selection and advance to the
next parameter.
Example: Valve #1
(master).
Example: Valve #2.
6.1.5.6
System size
Set the number of valves to be connected (2 to 4 valves) in the system.
Info
Only visible in multiple valve systems and only present on the master #1 valve.
Options:
• 2 valves in the system;
• 3 valves in the system;
• 4 valves in the system.
a) Adjust the system size with
and
.
ð
Default setting: 2 valves.
b) Press
to validate the selection and advance to the
next parameter.
6.1.5.7
Regeneration type
Select the regeneration type.
Options:
• time clock delayed: regeneration will take place, at the programmed regeneration
time, after the set amount of days has been reached (available only for system
type 4);
• volume delayed: regeneration is requested when the volume of treated water
reaches the reserve capacity and will take place, at the programmed regeneration
time (available only for system type 4);
• volume immediate: regeneration is requested when the capacity is fully depleted.
The regeneration starts immediately (available for all system types).
a) Set regeneration type with
and
.
b) Press
to validate the selection and advance to the
next parameter.
Summary of Contents for FLECK 3150 NXT
Page 1: ...FLECK 3150 NXT NXT2 INSTALLER MANUAL WATER PURIFICATION ...
Page 139: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 139 182 DC motor ...
Page 144: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 144 182 Ref MKT IM 010 C 18 10 2019 ...
Page 148: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 148 182 Ref MKT IM 010 C 18 10 2019 ...
Page 182: ...www pentairaquaeurope com ...