Installer manual Fleck 3150 NXT/NXT2 - Operation
Ref. MKT-IM-010 / C - 18.10.2019
129 / 182
Info
To cancel: press
(for NXT) or (for NXT2) again;
For NXT: The blue LED stop flashing and the letters SRV take place on the valve status;
For NXT2: The blue LED and the symbol
stop flashing.
8.3.2
Immediate regeneration
a) Press and hold
(for NXT) or (for NXT2) for 5 seconds to initiate immediate
manual regeneration, regardless from the programmed regeneration mode.
8.3.3
To advance regeneration cycles
a) Press
(for NXT) or (for NXT2) to pass to the next regeneration cycle.
8.3.4
To stop a regeneration (NXT2 only)
a) Press and hold to stop the regeneration.
8.4
Operation during a power failure
• All the program settings are stored in a permanent memory;
• current valve position, cycle step time elapsed, and time of day are stored during a
power failure, and will be restored upon power restoration;
• time is kept during a power failure and the time of day is adjusted upon restoration
of the power (as long as the power is restored within 12 hours);
• the time of day on the main display screen will flash after a power failure once the
power is restored until any button is pressed on the keyboard.
Summary of Contents for FLECK 3150 NXT
Page 1: ...FLECK 3150 NXT NXT2 INSTALLER MANUAL WATER PURIFICATION ...
Page 139: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 139 182 DC motor ...
Page 144: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 144 182 Ref MKT IM 010 C 18 10 2019 ...
Page 148: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 148 182 Ref MKT IM 010 C 18 10 2019 ...
Page 182: ...www pentairaquaeurope com ...