5.9
Bypassing
A bypass valve system should be installed on all water conditioning systems. Bypass
valves isolate the softener from the water system and allow unconditioned water to be
used. Service or routine maintenance procedures may also require that the system is
bypassed.
Softening
System
Normal operation
Softening
System
Out
In
Out
In
In Bypass
CAUTION
Do not solder pipes with lead-based solder.
CAUTION
Do not use tools to tighten plastic fittings. Over time, stress may break the connections.
CAUTION
Do not use petroleum grease on gaskets when connecting bypass plumbing. Use only
100% silicone grease products when installing any plastic valve. Non-silicone grease
may cause plastic components to fail over time.
5.10
Drain line connection
Info
Standard commercial practices are expressed here. Local codes may require changes
to the following suggestions. Check with local authorities before installing a system.
Mandatory
The drain line must be build with 2" PVC rigid tube. An air gap must be present at the
drain.
CAUTION
Flexible and semi-flexible hoses may bend and whip during draining.
The drain line may be elevated up to 1.8 m provided the run does not exceed 4.6 m and
water pressure at the softener is not less than 2.76 bar. Elevation can increase by
61 cm for each additional 0.69 bar of water pressure at the drain connector.
Where the drain empties into an overhead sewer line, a sink-type trap must be used.
Summary of Contents for FLECK 3150 NXT
Page 1: ...FLECK 3150 NXT NXT2 INSTALLER MANUAL WATER PURIFICATION ...
Page 139: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 139 182 DC motor ...
Page 144: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 144 182 Ref MKT IM 010 C 18 10 2019 ...
Page 148: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 148 182 Ref MKT IM 010 C 18 10 2019 ...
Page 182: ...www pentairaquaeurope com ...