Installer manual Fleck 3150 NXT/NXT2 - Programming
Ref. MKT-IM-010 / C - 18.10.2019
65 / 182
Parameter
Options
Definition
Note
REGEN TYPE
TIME CLK
DELAYED
Time clock delayed
(default)
System 4 only.
METER
IMMEDIAT
E
-
All system types.
MTR DLY
FIX RSV
Metered delayed fixed
reserve
Systems 4 & 6 only.
VALVE TYPE
2750
-
2850
-
2900/2910
-
3150
-
3900
-
STAGER-
NOTCH
CAM
-
REGENERANT
FLOW
DOWN
FLOW
-
UP FLOW
-
REMOTE
SIGNAL START
OFF to 99
minutes
-
This screen will not be displayed
for system type 14.
DISPLAY
FORMAT
US-
GALLONS
US units (default)
EU-
METRIC-
LITERS
Metric units
UNIT
CAPACITY
1 to
198’000
Gram CaCO
3
Use the SHIFT button to move to
the left.
CAPACITY
SAFETY
FACTOR
0 to 50
%
FEED WATER
HARDNESS
1 to 1’999
Milligram CaCO
3
/L
This screen will only display on
the lead unit for system types
6 & 7. For all other system types,
it will display for all units.
Use the SHIFT button to move to
the left.
TRIP POINT 1
1 to 3997
L/m
This screen will only display for
system 14 and will only appear on
the master controller (Valve
address #1).
Use the SHIFT button to move to
the left.
TRIP DELAY 1
30 to 99
Second
(30 seconds default)
Summary of Contents for FLECK 3150 NXT
Page 1: ...FLECK 3150 NXT NXT2 INSTALLER MANUAL WATER PURIFICATION ...
Page 139: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 139 182 DC motor ...
Page 144: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 144 182 Ref MKT IM 010 C 18 10 2019 ...
Page 148: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 148 182 Ref MKT IM 010 C 18 10 2019 ...
Page 182: ...www pentairaquaeurope com ...