Installer manual Fleck 3150 NXT/NXT2 - Programming
92 / 182
Ref. MKT-IM-010 / C - 18.10.2019
Parameter
Options
Definition
Note
TANK REFILL
0 to 240
Minute
Regenerant tank refill.
This screen will not be displayed
for filter systems.
PAUSE
0 to 240
Minute
This screen will not be displayed
for filter systems.
METER TYPE
GENERIC
-
Default flow meter type is based
on the valve type;
This screen will only display on
the lead (#1) unit for system
types 6, 7 & 8.
All other system types it will
display for all units;
This screen will only display
when regeneration type selected
is softener meter immediate or
delayed.
0.75"
PADDLE
(default for 2510)
0.75"
TURBINE
-
1.0"
PADDLE
(default for 2750)
1.0"
TURBINE
-
1.25"
TURBINE
-
1.5"
PADDLE
(default for 2815 and
2850)
1.5"
TURBINE
-
2.0"
PADDLE
(default for 2910 and
3150)
3.0"
PADDLE
(default for 3900)
PULSES/L
0 to 1500
PULSES/L
Only displayed if “Generic” is
chosen for the meter type.
MAXIMUM
FLOW - LPM
76 to 7570
l/min
CONTINUOUS
FLOW DETECT
ON
-
This screen will only display
when regeneration type selected
is softener meter immediate or
delayed.
OFF
(default)
CONTINUOUS
FLOW DETECT -
FLOW RATE-
LPM
0.1 to 227.1
l/min
Only displayed if continuous flow
detect is ON.
Even if maximum theoretical
programmable value is 999.9 l/
min, the controller will consider
only up to 227.1 l/min.
CONTINUOUS
FLOW DETECT -
DURATION
1 to 255
Hour
Only displayed if continuous flow
detect is ON.
Summary of Contents for FLECK 3150 NXT
Page 1: ...FLECK 3150 NXT NXT2 INSTALLER MANUAL WATER PURIFICATION ...
Page 139: ...Installer manual Fleck 3150 NXT NXT2 Maintenance Ref MKT IM 010 C 18 10 2019 139 182 DC motor ...
Page 144: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 144 182 Ref MKT IM 010 C 18 10 2019 ...
Page 148: ...Installer manual Fleck 3150 NXT NXT2 Maintenance 148 182 Ref MKT IM 010 C 18 10 2019 ...
Page 182: ...www pentairaquaeurope com ...