3.3.5 Alarms
Alarm Interface:
Warning:
Alarm/Alert:
Contact rating:
Relay contact (NC/NO, Common)
Relay contact (NC/NO, Common)
Max: AC:250V 6A
3.3.6 System electrical
LinerSCAN System
Power Input:
Power consumption:
24V DC
0.7A + (number of sensors x 0.2)
Fuse Rating:
Sensor Internal:
Terminal box #2:
1A Quick Blow
5A Quick Blow
Connections:
System to computer connector
Main terminals:
Alarms:
Air pressure warning switch:
Engine ON/OFF and Air ON/OFF:
Cable Gland ( x 4):
Follow Manufactures instruction.
Wago DIN rail Terminals, 2.5mm
2
Max.
Screw Terminals, 2.5mm
2
Max.
Captive clamp Screw Terminals, 0.5 to 1.5mm
2
Wago DIN rail Terminals, 2.5mm
2
Max.
13mm diameter max.
Cable Specifications
Approval:
Power:
Data, Alarm and Signals:
Cables must be shielded and approved for
Shipboard use.
Min 2.5mm
2
Twisted pair cable, shielded. Min 0.22 mm².
!
= Caution: LinerSCAN is classified as permanently connected equipment, and requires an
external isolating switch or circuit breaker. This must be clearly identifiable, labelled and positioned in
a readily accessible location.
3.3.7 System Plumbing
Scrapedown pipe weld boss
Internal thread:
Overall Length:
Outside diameter:
½ inch BSPP internal thread
37mm
27.2mm
Sensor Oil Flow connection:
½ inch BSPP Hydraulic fitting Female 60° cone
Sensor Oil Return connection:
½ inch BSPP Hydraulic fitting Female 60° cone
Oil flow and return pipe
½ inch (13mm) nominal internal diameter
Sensor air supply:
½ inch BSPP Female
Supplied with quick release couplings
Series 25/26 QR coupling to ½ inch BSP female
Series 25/26 QR coupling to 13mm hose tail
Max air line pressure for Air Blast
10 bar [145psi]
Minimum flow rate
30 litres per minute
Minimum Pressure
Scavenge Pr 1 bar [15psi]
Air pressure warning switch
1/4 inch BSPP
Summary of Contents for FG-K17401-KW
Page 9: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 8 of 93 3 Installation Installation ...
Page 34: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 33 of 93 4 Commissioning Commissioning ...
Page 40: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 39 of 93 5 Operation Operation Manual ...
Page 89: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 88 of 93 ...