MA-K17510-KW LinerSCAN manual ISSUE P.doc
Page 65 of 93
The same engineer re-visited the vessel since this event to carry out the same 6 monthly inspection on
cylinders 1, 2 and 10. This time the process had been streamlined and improved. Subsequent wear debris
levels only went as high as 450ppm, a considerable improvement.
Figure 9 Damaged caused by routine maintenance
Below, shows the levels of wear occurring after maintenance. The vertical green indicates when the
engine is started. It is not uncommon for high values to be observed after a scavenge space clean or
inspection, since accumulated iron particles are commonly dislodged during the process.
Summary of Contents for FG-K17401-KW
Page 9: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 8 of 93 3 Installation Installation ...
Page 34: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 33 of 93 4 Commissioning Commissioning ...
Page 40: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 39 of 93 5 Operation Operation Manual ...
Page 89: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 88 of 93 ...