MA-K17510-KW LinerSCAN manual ISSUE P.doc
Page 6 of 93
2.5 Important: Safety Summary
This equipment is designed to comply with EN61010-1.
Warning: This equipment has not been approved for use in an explosive atmosphere.
Please ensure you thoroughly read and understand this user document before attempting to install or
operate the LinerSCAN range of wear debris sensors covered in this manual, derivatives or related
equipment.
If the equipment is used in a manner, or for a specific purpose other than that described in this
manual, then any safety protection may be impaired.
The sensors are designed to be connected to pressurised systems – including pneumatic
(Compressed Air) lines and hydraulic systems. A responsible body, the end user or system integrator
is responsible for ensuring the safety of associated systems, hoses or pipe-work containing fluids. This
includes isolation for maintenance to the sensor(s).
This equipment must be installed and operated by qualified persons only.
!
Caution:
The sensors are connected together in this application by waste cylinder lubricant drain pipes, the
scavenge space and common compressed air and electrical power supplies.
Therefore when maintenance is undertaken all common supplies [power, air, oil and drain] need
turning off [disconnecting at source] or the valves to the sensor closed to isolate the sensor from the
system [recommended]. Open the main drain valve to allow the engine to function.
!
Caution:
•
Never use the sensor near combustible gases or liquids.
•
Never disassemble, repair, or tamper with the sensor.
•
Ensure that the supply voltage is within the specifications and means of isolation fitted.
•
Ensure the load currents do not exceed the rated values.
•
Ensure all associated equipment and pipe-work specification is the same or greater than the
operating specifications for the sensor.
•
Check all associated equipment and pipe-work for correct connection before powering the unit.
•
Check all wiring for correct connection before powering the unit.
•
Never weld to a pipe which contains or has contained oil
•
The sensor case must be earthed
Summary of Contents for FG-K17401-KW
Page 9: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 8 of 93 3 Installation Installation ...
Page 34: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 33 of 93 4 Commissioning Commissioning ...
Page 40: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 39 of 93 5 Operation Operation Manual ...
Page 89: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 88 of 93 ...