Stage 3
Membrane Filtration
Waste
Water
Out
MAX24, MAX50 Parts List:
MAX35HIS, MAX60HiS Parts List:
Part#
CF1M
1 Micron
Sediment
Filter
Part#
GHF
Garden
Hose
Fitting
Part#
GHF
Garden
Hose
Fitting
Part#
CFCE
Matrix
Carbon
Filter
Part#
CFI
Mixed-Bed
Deion
Resin
Cartridge
Part#
SILICAMAX
High
Silicate
Removal
Deion
Resin
Cartridge
Part#
CFCE
Matrix
Carbon
Filter
Part#
CF1M
1 Micron
Sediment
Filter
Canister Wrench
Canister Wrench
Part #:
MTFC50
,
MTFC24
Membrane
Part #:
MHIS35,
MHiS60
Membrane
Membrane Insertion:
Disconnect the yellow tube that runs from the prefilter to the
membrane housing’s cap. Unscrew this cap, and, if needed,
re-seat the housing’s o-ring(see diagram 2). Remove
membrane from protective plastic bag.
DO NOT REMOVE
PROTECTIVE TAPE FROM AROUND MEMBRANE!
The
membrane has a plastic pipe located in the center of the
membrane material. At one end of the pipe, there are two
small black o-rings. Hold the housing vertically and insert the
membrane with the two small, black o-rings first(see diagram
2). It will stop at the large black gasket seal located on the
outer edge of the membrane material. Take the palm of your
hand and push the membrane into the housing. This is
sometimes a tight fit so push with adequate force. You will
feel it “seat” into the housing.
Diagram 1
Membrane
Housing
Housing
O-Ring
Membrane
Diagram 2
Once the membrane is “seated”,
you can check to make sure it is all
the way in. From the top of the
membrane material to the edge of
the housing lip should measure
about 3/4 of an inch(see diagram
3). If it is not this far in, you will
have to either, re-insert the
membrane, or try to push it farther
inside. Once the membrane is
seated properly, screw the housing
cap onto the housing and re-attach
the yellow tube as before.
3/4“ Space
Stage
1
Stage
2
Stage 4
™
CFI or SILICAMAX(
Hi-S
)
Tap Water In
Product
Water
Out
Model #
MAX24, MAX50
MAXHIS35, MAXHiS60
Front View
Rear View
1
1
1
1
1
1
1
1
1
1
1
1
Diagram 3
Waste Water (Orange tubing)
Product Water (Yellow Tubing)
Membrane Housing
Flow Restrictor Diagram
This is shown for reference only.
All units have their flow restrictors
PRE-
®
INSTALLED
at Kent Marine This
component has no adjustment and
should not be removed or tampered with
Housing Cap
Prefiltered
Water In
The Membrane Housing
JacoNut
Orange Tubing
Split
Compression
Ring
Compression
Collar
REV. 2
®