Stage 3

Membrane Filtration

Waste 

Water

Out

MAX24, MAX50 Parts List:

MAX35HIS, MAX60HiS Parts List:

Part#

CF1M

1 Micron

Sediment 

Filter

Part#

GHF

Garden

Hose

Fitting

Part#

GHF

Garden

Hose

Fitting

Part#

CFCE

Matrix

Carbon

Filter

Part#

CFI

Mixed-Bed

Deion

Resin

Cartridge

Part#

SILICAMAX

High 

Silicate

Removal

Deion

Resin

Cartridge

Part#

CFCE

Matrix

Carbon

Filter

Part#

CF1M

1 Micron

Sediment 

Filter

Canister Wrench

Canister Wrench

Part #:

 

MTFC50

,

 

MTFC24

Membrane

Part #:

 

MHIS35,

 

MHiS60 

Membrane

Membrane Insertion:

Disconnect the yellow tube that runs from the prefilter to the 
membrane housing’s cap.  Unscrew this cap, and, if needed, 
re-seat the housing’s o-ring(see diagram 2).  Remove 
membrane from protective plastic bag.  

DO NOT REMOVE 

PROTECTIVE TAPE FROM AROUND MEMBRANE!

 The 

membrane has a plastic pipe located in the center of the 
membrane material.  At one end of the pipe, there are two 
small black o-rings.  Hold the housing vertically and insert the 
membrane with the two small, black o-rings first(see diagram 
2).  It will stop at the large black gasket seal located on the 
outer edge of the membrane material.  Take the palm of your 
hand and push the membrane into the housing.  This is 
sometimes a tight fit so push with adequate force.  You will 
feel it “seat” into the housing.    

Diagram 1

Membrane

Housing

Housing
O-Ring

Membrane

Diagram 2

Once the membrane is “seated”, 
you can check to make sure it is all 
the way in.  From the top of the 
membrane material to the edge of 
the housing lip should measure 
about 3/4 of an inch(see diagram 
3).  If it is not this far in, you will 
have to either, re-insert the 
membrane, or try to push it farther 
inside.  Once the membrane is 
seated properly, screw the housing 
cap onto the housing and re-attach 
the yellow tube as before.

3/4“ Space

Stage 

1

Stage 

2

Stage 4

CFI or SILICAMAX(

Hi-S

)

Tap Water In

Product 

Water

Out

Model #

MAX24, MAX50

MAXHIS35, MAXHiS60

Front View

Rear View

1

1

1

1

1

1

1

1

1

1

1

1

Diagram 3

Waste Water (Orange tubing)

Product Water (Yellow Tubing)

Membrane Housing

Flow Restrictor Diagram

This is shown for reference only.

All units have their flow restrictors 

PRE-

®

INSTALLED

 at Kent Marine   This 

component has no adjustment and 
should not be removed or tampered with 

Housing Cap

Prefiltered 

Water In

The Membrane Housing 

JacoNut

Orange Tubing

Split 

Compression

Ring

Compression

Collar

REV. 2

®

Copyright 1999, Kent Marine , Inc.

®

Copyright 1999, Kent Marine , Inc.