MA-K17510-KW LinerSCAN manual ISSUE P.doc
Page 18 of 93
3.7 Installation of LinerSCAN
This section is arranged in order of installation task.
!
Caution:
DO NOT CONNECT POWER TO LinerSCAN NETWORK UNTIL DIRECTED.
!
Caution:
Ensure all tasks in the pre-installation manual MA-K17500-KW are complete before
proceeding.
3.7.1 Unpack the sensors and Install kit
Unpack all equipment and check delivery for all parts. Notify Kittiwake immediately of missing or
damaged parts. Ensure that all additional (Non-Kittiwake supplied) equipment and accessories
necessary for installation are present before proceeding.
3.7.2 Install PC at desired location
Ensure the PC is securely mounted and that connections to and from PC are secure and not easy to
pull out.
3.7.3 Fit LinerSCAN sensor to the mounting bracket
This will have been prepared under pre-installation work. Affix vinyl numbers to sensors for ease of
identification.
3.7.4 Make the oil and air connections
Make connections in accordance with the ‘General Information’ section, and drawing RS-096 –
detailed in the pre-installation manual MA-K17500-KW.
3.7.5 Connect Sensor to Sensor
Fit the pre-wired cables between the sensors and terminal box – fit the terminating plug to the last
sensor
3.7.6 Terminate and connect all pre-Installed Cable runs
Connections are made in accordance with the ‘General Information’ section. Ensure all power is ‘OFF’
and check wiring connections.
Summary of Contents for FG-K17401-KW
Page 9: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 8 of 93 3 Installation Installation ...
Page 34: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 33 of 93 4 Commissioning Commissioning ...
Page 40: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 39 of 93 5 Operation Operation Manual ...
Page 89: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 88 of 93 ...