MA-K17510-KW LinerSCAN manual ISSUE P.doc
Page 11 of 93
3.2 LinerSCAN - What is not included
LinerSCAN is supplied as a core group of components. Since each ship installation is unique, the level
of additional equipment will vary. Below is a general list of required equipment:
•
Air Line Fittings, Valves and Hose
•
Computer
•
Cable
•
24V Power supply
•
Sensor mountings, Brackets and fasteners
3.3 Technical Data
3.3.1 Sensor performance
Detection
0-2000 parts per million [ppm]
Un-combined ferrous debris by weight
Accuracy
+/-30ppm
3.3.2 Sensor General
Zeroing method :
Air Blast
Zeroing synchronisation method :
Sensor controlled solenoid valve
Sensor bore diameter
10mm
Permitted Fluid temperature :
10 to 65°C
Ambient operating temperature:
0-65°C
IP rating:
Enclosure
Internal components
IP24
IP65
Weight:
17kg
Size:
300 x 300 x 150mm (H x W x D)
3.3.3 Terminal Box
Ambient operating temperature:
0-65°C
IP rating:
IP65
Weight:
5kg
Size:
200 x 400 x 125mm (H x W x D)
3.3.4 LinerSCAN software: PC requirements
Operating System
Microsoft Windows XP, Service Pack 2 or later’
Microsoft Windows 7
Minimum screen resolution
1200 x 800
Connections
2 free USB ports
Summary of Contents for FG-K17401-KW
Page 9: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 8 of 93 3 Installation Installation ...
Page 34: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 33 of 93 4 Commissioning Commissioning ...
Page 40: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 39 of 93 5 Operation Operation Manual ...
Page 89: ...MA K17510 KW LinerSCAN manual ISSUE P doc Page 88 of 93 ...