![Parker 650S Series Product Manual Download Page 87](http://html.mh-extra.com/html/parker/650s-series/650s-series_product-manual_755635087.webp)
6-36
Programming Your Application
650S AC Drive
** Power Dependent Parameters
These parameters (marked with “**” in the Application diagrams) are set to a value depending on the drive's overall “power-
build” indicated by the Product Code. We recommend that you do not change the Product Code.
230V Build Power Dependent Defaults
Frame 1
Frame 2
Parameter
Function Block
Tag
0.25kW
0.37kW
0.55kW
0.75kW
1.1kW
1.5kW
ACCEL TIME
REFERENCE RAMP
258
10.0 s
10.0 s
10.0 s
10.0 s
10.0 s
10.0 s
DECEL TIME
REFERENCE RAMP
259
10.0 s
10.0 s
10.0 s
10.0 s
10.0 s
10.0 s
SPEED PROP GAIN
SPEED LOOP
1187
20 20
20
20
20
20
SPEED INT TIME
SPEED LOOP
1188
500. ms
500. ms
500. ms
500. ms
500. ms
500. ms
BRAKE RESISTANCE
DYNAMIC BRAKING
77
500 500
500
500
500
500
400V Build Power Dependent Defaults
Frame 2
Parameter
Function Block
Tag
0.37kW
0.55kW
0.75kW
1.1kW
1.5kW
2.2kW
ACCEL TIME
REFERENCE RAMP
258
10.0 s
10.0 s
10.0 s
10.0 s
10.0 s
10.0 s
DECEL TIME
REFERENCE RAMP
259
10.0 s
10.0 s
10.0 s
10.0 s
10.0 s
10.0 s
SPEED PROP GAIN
SPEED LOOP
1187
20 20
20
20
20
20
SPEED INT TIME
SPEED LOOP
1188
500. ms
500. ms
500. ms
500. ms
500. ms
500. ms
BRAKE RESISTANCE
DYNAMIC BRAKING
77
500 500
500
200
200
200
400V Build Power Dependent Defaults
Frame 3
Parameter
Function Block
Tag
ACCEL TIME
REFERENCE RAMP
258
10.0 s
10.0 s
10.0 s
10.0 s
DECEL TIME
REFERENCE RAMP
259
10.0 s
10.0 s
10.0 s
10.0 s
SPEED PROP GAIN
SPEED LOOP
1187
20
20
20
20
SPEED INT TIME
SPEED LOOP
1188
500. ms
500. ms
500. ms
500. ms
BRAKE RESISTANCE
DYNAMIC BRAKING
77
100
100
56
56