3-10
Installing the Drive
650S AC Drive
Control Wiring
Control wiring of between 0.08mm
2
(28AWG) and 2.5mm
2
(12AWG) can be used. Ensure all wiring is rated for the highest
system voltage. All control terminals are SELV, i.e. double-insulated from power circuits.
Using Cage Clamp Terminals
Strip wire insulation to 5-6mm (0.20-0.24 inches), or alternatively use wire-crimps. Use a flat-bladed
screwdriver, maximum blade size 3.5mm. The cage provides the correct force for a secure
connection.
IMPORTANT: