![Parker 650S Series Product Manual Download Page 20](http://html.mh-extra.com/html/parker/650s-series/650s-series_product-manual_755635020.webp)
Installing the Drive
3-5
650S AC Drive
To motor thermistor,
li nk termi nals
TH1A and TH1B
Minimum Connections for Application 1:
AOUT2
(10V)
Reference
Start
1
2
4
6
7
0V
AIN1
+24V
DIN1
Speed
Single Wire Starting
Reference
Stop
1
2
4
6
7
0V
AIN1
+24V
DIN1
Speed
10
Start
Push-Button Starting
DIN4/DOUT2
norm ally-closed
pushbutton
norm ally-open
pushbutton
switch
2-position
AOUT 2
(10V)
Remote Control Wiring
If operating in Remote Control you will use your control panel to start and stop the drive, via a speed potentiometer and
switches or push-buttons.
The diagram below shows the
minimum
connections to operate the drive for single-wire (switch) starting, and push-button
starting.
Referring to the Connection Diagram:
•
Follow the instructions for Local Control Wiring, as detailed previous
•
Install using minimum connections
Note:
You can still operate the drive in Local mode, if necessary, with any Application selected.
Refer to Chapter 4: "Operating the Drive" and follow the relevant instructions for Single Wire Starting or Push-Button
Starting.
WARNING!
This product is designated as “professional equipment”
as defined in EN61000-3-2. Where enforced, permission of the supply authority shall be obtained before connection to the low voltage
domestic supply.
Ensure that all wiring is electrically isolated and cannot be made “live” unintentionally by other personnel.
The drive is suitable for use with both earth referenced supplies (TN) and non-earth referenced supplied (IT) when fitted with an
internal ac supply EMC filter.