12-8
Applications
650S AC Drive
Application 3 : Preset Speeds
Preset Speeds
IDEAL FOR APPLICATIONS REQUIRING
MULTIPLE DISCRETE SPEED LEVELS
p2
Max speed
p3
Min speed
p4
Accel time
p5
Decel time
p8
Jog setpoint
p9
Stop mode
p99
Password
STANDARD PARAMETERS
Italic text indicates Default
(SCALABLE)
Speeds
Preset
1 Setup
2 Clean
3 Operate 1
4 Operate 2
Frequency Hz
Speed Setpt %
DC Link Volts V
Motor Current A
DIAGNOSTICS
SPEED DEMAND
SEQUENCING LOGIC
RAMP
TORQUE LIMIT
P4 ACCEL TIME
P5 DECEL TIME
PWM CONTROL
V
F
I FDBK
I
FWD/REV
MIN/MAX SPEED
P9 STOP MODE
P9 STOP MODE
DIN4/
DIN3 DIN2 PRESET
0V
0V
0V
0V
0V
24V
0V
24V
0V
0V
24V
24V
24V
0V
0V
24V
0V
24V
24V
24V
0V
24V
24V
24V
0
1
2
3
4
5
6
7
RL1A
RL1B
User
Relay
R
OPD3 RELAY
SPEED INT TIME
SPEED PROP GAIN
P2 MAX SPEED
P3 MIN SPEED
PRESET 0
PRESET 1
PRESET 2
PRESET 6
PRESET 5
PRESET 4
PRESET 3
PRESET 7
DOUT2
0V
AIN1
AIN2
+10V REF
AOUT
+24V
DIN
1
DIN
2
DIN3
AUTO REF
MAN
.
REF
PRESET IN
START/STOP
PRESET IN
PRESET IN
Speed
Meter
(at default
1 setting)
1
2
3
4
5
6
7
8
9
10
11
12
13
DOUT2
0 NONE
1 HEALTH
2 TRIPPED
3 RUNNING
4 AT ZERO
5 AT SPEED
6 AT LOAD
DIN5
NOT COAST STOP
DIN4/
SPEED LOOP
MAIN TORQUE LIM
AP01
AP02
AP03
AP04
AP05
AP06
AP07
AP08