COMSPHERE 3600 Series Data Service Units
C-16
July 1999
3610-A2-GB91-90
Table C-10
(3 of 8)
TDM/MCMP/Bridge Configuration Error Messages
Message
Action
Condition
Ext Time undspd
TDM mode: The port selected as the
source of external timing (the
TxClkSource configuration option is
set to port number in the DSU and/or
DBM configuration submenu) is also
an underspeed port.
A port cannot be the source of
external timing and also run
underspeed.
Correct the problem in one of two
ways:
1. Configure another synchronous
port as underspeed via the
appropriate path (DSU or DBM) in
the PrtSp configuration submenu.
2. Configure another port to provide
external timing.
Elast Not Valid
Bridge mode: An attempt is made to
configure a DSU as an extended
bridge with elastic store turned ON at
one or more of the active bridge
ports, and the Bridge Rate
configuration option is set to any
value but =DSU. Bridge Rate is a
configuration option in the Setup path
of the MUX configuration submenu.
For an extended bridge configuration
where Bridge Rate is set to any value
but =DSU, elastic store must be
turned Off at each of the active bridge
supports.
Set configuration option ElasStor
(Elastic Store) to Disab for each of
the active bridge ports via the
appropriate path (Prt2—Prt6) in the
MUX configuration submenu.
FEP Speeds diff
TDM or MCMP mode: The two ports
in the FEP port-sharing group are
assigned to different speeds.
Both ports in an FEP port-sharing
group must be assigned to the same
speed.
Assign the same speed to both ports
in an FEP port-sharing group via the
appropriate path, DSU or DBM, in the
PrtSp configuration submenu.
FEP&ShrDv Incmpt
TDM or MCMP mode: An attempt is
made to place a port into both a
digital-sharing group and an FEP
port-sharing group.
A port cannot be included in a
digital-sharing group and an FEP
port-sharing group at the same time.
Select which of the groups is to have
the port via the Setup path in the
MUX configuration submenu.
Incmpt Diag mode
Mixed diagnostic type is not
compatible with point-to-point or
MCMP operation.
Select another mode of operation via
the Setup path in the MUX
configuration submenu, or select
another diagnostic type via the
Diagnostic DSU or DBM option set.
Summary of Contents for COMSPHERE 3610
Page 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices ...
Page 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90 ...
Page 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2 ...
Page 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90 ...
Page 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90 ...
Page 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A ...
Page 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90 ...
Page 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999 ...
Page 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90 ...
Page 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90 ...
Page 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F ...
Page 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90 ...
Page 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90 ...
Page 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90 ...
Page 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90 ...