COMSPHERE 3600 Series Data Service Units
6-56
July 1999
3610-A2-GB91-90
Table 6-18
(1 of 2)
LPDA-2 Configuration Options
LPDA-2: Disab
Next Enab Disab Prev
LPDA-2 Operation. Allows the DSU to respond to LPDA-2 commands issued from NetView
t
. This
configuration option must be enabled at the control DSU and each tributary DSU for proper SNA Diagnostic
Interface operation.
When a disruptive test is running at the control DSU, the FEP reports Test in Progress to the NetView
operator when the operator issues an LPDA-2 command. If the Test Mode (TM) jumper at the control DSU is
disabled, the control DSU may respond to an LPDA-2 command while running a test initiated by the NMS or
DCP. (The LPDA-2 command cannot propagate any farther than the control.) However, if the control DSU is
performing a Device Test or an End-to-End test, it ignores any NetView-initiated command.
Enab
—
The 3600 Series DSU responds to LPDA-2 commands. When enabled, it is recommended that
DSR FrcOn be set to Enab and CTS Cntrl set to RTS.
Disab
—
The 3600 Series DSU does not respond to LPDA-2 commands.
LPDA Address: 001
Next Chang Prev
LPDA Address. Allows the LPDA-2 address used by NetView to be set. Choices are 1 through 255, in
decimal.
The following rules apply to control DSU address assignment:
1.
Link Segment Level 1 (Primary Circuit). The control DSU closest to the NetView host is typically
assigned the address
1.
2.
Link Segment Level 2 (Extended Circuit). The extended control DSU is typically assigned the address
2.
The following rules apply to tributary DSU address assignment:
1.
Valid Addresses. Valid addresses for tributary DSUs range from 1 to 255.
2.
Single DTE. The tributary DSU address is set to the Physical Unit (PU) address of the attached terminal
device. This constraint is imposed by NetView.
3.
Extended Circuit. For configurations having extended circuits, the tributary DSU in the primary circuit is
set to 253. Address 253 (FD hex) is the broadcast LPDA-2 address.
Order the
COMSPHERE 3600 Series Data Service Units, Models 3610 and 3611, Time Division Multiplexer,
Multichannel Multipoint, and Digital Bridge Options, User’s Guide Supplement for additional addressing rules
applying to TDM, MCMP, and digital sharing.
Summary of Contents for COMSPHERE 3610
Page 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices ...
Page 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90 ...
Page 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2 ...
Page 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90 ...
Page 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90 ...
Page 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A ...
Page 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90 ...
Page 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999 ...
Page 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90 ...
Page 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90 ...
Page 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F ...
Page 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90 ...
Page 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90 ...
Page 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90 ...
Page 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90 ...