DSU Operations
4-11
3610-A2-GB91-90
July 1999
Select the port you want to view using the F1 (
↑
) and
F2 (
↓
) keys, then press the F3 key to display (Displ) the
status of the DTE port. For this example, Port 3 was
selected.
Results
The following report displays the DTE interface states
for the local or remote DSU selected. This report shows
the activity at the DTE interface, and may be different
from the states displayed by the DSU’s LED indicators
which sometimes reflect the internal states of the interface
circuits. In this example, Port 1 was designated.
F1
Prt03
DTE Stats:
TXD
RXD DSR
F2
F3
From the DCP, the DTE interface statuses are
displayed in sets. Use the
key to scroll the next set of
lead statuses into view. Table 4-3 lists the DTE lead status
codes.
Table 4-3
DTE Lead Status Codes
Code
Lead Status
ON/SPACE (above text line)
Off/MARK (below text line)
At least one transition between
Off/MARK and ON/SPACE has
been detected during the
monitoring window.
Circuit Quality Status
Circuit Quality (CircQ) status displays the level and
quality of the signal being received from the network by
the DBM. (This report is only available for a V.32 DBM.)
Refer to COMSPHERE 3600 Series Data Service
Units, Models 3610 and 3611 Dial Backup Module and
SNA Diagnostic Interface Options, Applications Guide for
Circuit Quality information.
Identity
Identity (ID) displays a report listing a DSU’s model
number, serial number, software/firmware version,
network address, DDS rate, DBM rate, and the DBM type
installed.
To access the DSU’s Identity report from the top-level
menu, make the following selections:
•
Local (F1), or Remot (F2) and Address
•
Stat
•
ID
Results
You can display the Identity report for a local or
remote device. The following is an example screen:
F1
Identity:
Model: 3610
F2
F3
Table 4-4
lists the Identity report information provided
about a DSU and its options. Press the
key to display
additional information, one display at a time.
Summary of Contents for COMSPHERE 3610
Page 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices ...
Page 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90 ...
Page 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2 ...
Page 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90 ...
Page 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90 ...
Page 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A ...
Page 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90 ...
Page 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999 ...
Page 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90 ...
Page 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90 ...
Page 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F ...
Page 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90 ...
Page 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90 ...
Page 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90 ...
Page 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90 ...