COMSPHERE 3600 Series Data Service Units
4-26
July 1999
3610-A2-GB91-90
Table 4-7
End-to-End Test Results
Results
Reported By
1
Information Displayed
Time:
Local and Remote
DSU/DBM
Running test timer. (The Clr selection resets the timer to
0:00:00.)
Tot Block:
Local and Remote
DSU/DBM
Number of blocks completed. (The Clr selection resets the
counter to 0.)
Rx Blk err:
Local and Remote
DSU/DBM
Number of incoming blocks with errors detected, indicating a
fault in the incoming transmission path. (The Clr selection resets
the counter to 0.)
Tx Blk err:
Local and Remote
DSU/DBM
Number of blocks with errors detected at the remote DSU,
indicating a fault in the outgoing transmission path. (The Clr
selection resets the counter to 0.)
Rx TimOuts:
Local DSU/DBM only
Number of blocks that were not received or acknowledged by
the remote DSU or DBM. (The Clr selection resets the counter
to 0.)
1
Local refers to the test initiator.
Bit Error Rate Test
The Bit Error Rate Test (BERT) is a session-
disruptive test used to analyze the network circuit. This
test requires network connection to the control and
tributary DSUs. A DTE connection to the remote DSU
may be required. The originating DSU sends a continuous
511-bit test pattern from its test pattern generator
(
Figure 4-11
), transmitting it via the DDS circuit for the
DSU test and via the dial circuit for the DBM test. It can
monitor the results in one of the following ways:
•
Putting the remote DSU into Digital Loopback and
checking the returned pattern for errors
(
Figure 4-11, part A
).
•
Simultaneously executing the BERT in the remote
DSU (
Figure 4-11, part B
).
If using external test equipment that transmits a
standard 511-bit pseudo-random test pattern, make sure
the DSU is configured for the standard 511 test pattern. If
the remote end is a 2500 or 2600 DSU, it will transmit an
inverted 511 test pattern. Make sure the 3600 Series DSU
is configured for the AT&T test pattern.
The test continues until aborted. This test can be run on
an aggregate or per-port basis. When run on an aggregate
basis, in-band secondary channel transport
communications are disrupted.
A control DSU can initiate a Bit Error Rate Test on a
point-to-point or multipoint network. A tributary DSU can
only initiate a BERT on a point-to-point network.
If nondisruptive diagnostics are in effect, the in-band
secondary channel transport communications are
disrupted. The Bit Error Rate Test is not available in
Bridge mode.
To access BERT from the top-level menu, make the
following selections:
•
Local (F1), or Remot (F2) and Address
•
Test
•
DSU (select active core)
•
BERT
F1
DSU BERT:
Start
Displ
Clr
F2
F3
If the BERT is already in progress, Start will not be
displayed. The Port Select screen appears.
To abort the Bit Error Rate Test, press the
key
twice. To display the results of the test, press F1 to select
Summary of Contents for COMSPHERE 3610
Page 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices ...
Page 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90 ...
Page 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2 ...
Page 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90 ...
Page 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90 ...
Page 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A ...
Page 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90 ...
Page 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999 ...
Page 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90 ...
Page 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90 ...
Page 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F ...
Page 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90 ...
Page 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90 ...
Page 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90 ...
Page 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90 ...