COMSPHERE 3600 Series Data Service Units
C-14
July 1999
3610-A2-GB91-90
TDM/MCMP/Bridge Messages
The following messages only appear when a time
division multiplexer (TDM) or multichannel multipoint
(MCMP) circuit card is installed. Table C-10 lists possible
error messages that could result when a TDM, MCMP, or
digital bridge is part of your system configuration.
Table C-10
(1 of 8)
TDM/MCMP/Bridge Configuration Error Messages
Message
Condition
Action
All Async >Aggr
TDM mode: All ports are configured
for asynchronous operation and their
combined corresponding
synchronous rate exceeds the value
for the DSU/DBM configuration option
Rate(Kbps).
If all ports are assigned to
asynchronous operation, the sum of
the corresponding synchronous port
speeds must be less than the value of
the DSU/DBM rate.
You can correct the problem in one of
two ways:
1. Set the Rate(Kbps) of the DSU or
DBM Rate configuration option to
a higher value.
2. Lower the DSU/DBM port speeds
via the selection DSU or DBM in
the PrtSp configuration submenu.
Async Undspeed
TDM mode: An attempt was made to
run an asynchronous port at
underspeed.
A port configured for asynchronous
operation cannot be configured to run
underspeed.
Choose a synchronous port and
configure it for underspeed via the
appropriate path (DSU or DBM) in the
PrtSp configuration submenu.
Chan >1 in FEPGrp
Both ports in a FEP port-sharing
group must be assigned to the same
channel.
Assign the same channel to both
ports in an FEP port-sharing group
via the Chan path in the PrtSp
configuration submenu.
Chan >1 in ShrGrp
MCMP mode: An attempt is made to
recreate a digital-sharing group using
configuration options Sharing Device,
Lowest Port Number, and Number of
Ports in Group in the Setup path of
the MUX configuration submenu, and
not all ports in the digital-sharing
group are assigned to the same
channel.
All ports in a digital-sharing group
must be assigned to the same
channel.
Assign the same channel to all ports
in a digital-sharing group via the
Chan path in the PrtSp configuration
submenu.
Ctrl Type Requir
Bridge mode: An attempt is made to
place a DSU configured as a tributary
into Bridge mode.
Bridge mode requires that the DSU
be configured as a control.
Set the Position configuration option
in the DSU submenu to Cntrl.
Summary of Contents for COMSPHERE 3610
Page 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices ...
Page 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90 ...
Page 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2 ...
Page 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90 ...
Page 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90 ...
Page 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A ...
Page 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90 ...
Page 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999 ...
Page 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90 ...
Page 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90 ...
Page 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F ...
Page 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90 ...
Page 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90 ...
Page 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90 ...
Page 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90 ...