COMSPHERE 3600 Series Data Service Units
4-10
July 1999
3610-A2-GB91-90
Expanded Health and Status
The Expanded Health and Status (Expan) selection
only appears during automatic dialing. It retrieves the
Health and Status report for the local DSU when a dialing
attempt failure or unsolicited disconnect occurs after a
successful connection.
NOTE
The Expan selection only appears
if there is expanded health and
status to report.
Results
The first line of the Expanded Health and Status report
displays the report name. The second line displays one or
more of the test or fault messages listed in
Appendix C
.
The format of the Expanded Health and Status screen
is shown below:
F1
Expanded H/S:
→
Message
F2
F3
The
→
indicates that there is another message to be
read.
Subnetwork Health and Status
Subnetwork Health and Status (Subn) displays health
and status information from a DSU’s subnetwork (that is,
all DSUs and/or DBMs assigned to that DSU’s active poll
list).
NOTE
The Subn selection only appears
for nondisruptive diagnostics
(Diag Type = NonD) in Local
mode.
The downstream DSU’s network address and status is
displayed on the first line. Press the F1 (
↑
) key to display
the next highest network address; press the F2 (
↓
) key to
display the next lowest network address.
Results
The following report displays Subnetwork Health and
Status for an active poll list member:
F1
H/S:
027
Normal
F2
F3
If no downstream DSU’s are being monitored, No
PList is displayed instead of the address and status. Refer
to
Appendix C
for a list of the Subnetwork Health and
Status statuses and their meaning.
DTE Status
DTE status displays a snapshot of the status of the
external DTE interface of the local or remote DSU/DBM.
Ten different signal statuses are reported. For the local
DSU status, the display is sampled and updated every
2 seconds. For the remote DSU status, only one set of
states is returned based upon a monitoring period of
approximately 3 seconds.
To access the DTE status report from the top-level
menu, make the following selections:
•
Local (F1), or Remot (F2) and Address
•
Stat
•
DTE
If only one port is active, the DTE Status screen is
displayed. If more than one port is active, the Port screen
is displayed prior to the DTE Status screen.
The following example shows the Port Number screen:
F1
Port Number:
3
Displ
F2
F3
Summary of Contents for COMSPHERE 3610
Page 4: ...COMSPHERE 3600 Series Data Service Units C July 1999 3610 A2 GB91 90 Notices ...
Page 16: ...COMSPHERE 3600 Series Data Service Units x July 1999 3610 A2 GB91 90 ...
Page 27: ...Introduction 1 11 3610 A2 GB91 90 July 1999 Figure 1 4 NMS Interfaces to the SDU 1 of 2 ...
Page 128: ...COMSPHERE 3600 Series Data Service Units 5 6 July 1999 3610 A2 GB91 90 ...
Page 186: ...COMSPHERE 3600 Series Data Service Units 6 58 July 1999 3610 A2 GB91 90 ...
Page 187: ...A 1 3610 A2 GB91 90 July 1999 Data Service Unit Menu A ...
Page 188: ...COMSPHERE 3600 Series Data Service Units A 2 July 1999 3610 A2 GB91 90 ...
Page 189: ...Data Service Unit Menu A 3 3610 A2 GB91 90 July 1999 ...
Page 190: ...COMSPHERE 3600 Series Data Service Units A 4 July 1999 3610 A2 GB91 90 ...
Page 224: ...COMSPHERE 3600 Series Data Service Units C 22 July 1999 3610 A2 GB91 90 ...
Page 259: ...Pin Assignments F 11 3610 A2 GB91 90 July 1999 Figure F 8 EIA 232 D Crossover Cable 4951 035F ...
Page 272: ...COMSPHERE 3600 Series Data Service Units H 6 July 1999 3610 A2 GB91 90 ...
Page 278: ...COMSPHERE 3600 Series Data Service Units I 6 July 1999 3610 A2 GB91 90 ...
Page 280: ...COMSPHERE 3600 Series Data Service Units J 2 July 1999 3610 A2 GB91 90 ...
Page 292: ...COMSPHERE 3600 Series Data Service Units L 10 July 1999 3610 A2 GB91 90 ...