Page 1: ...uppauge N Y 11788 USA TEL 631 273 0404 FAX 631 273 1638 INTERNET http www commspecial com EMAIL info commspecial com Communications Specialties Pte Ltd 100 Beach Road 22 09ShawTower Singapore189702 Tel 65 6391 8790 FAX 65 6396 0138 Internet www commspecial com Email csiasia commspecial com P N 102181 Rev E ...

Page 2: ...e 5002 5002 To RS 232 Port To RS 232 Port P P Operating Power May Be Applied Through The P Port or Through The DB 25 Connector Pins Typical Drop and Repeat System Configuration T R T R Fiber Optic Cable 5002 Set to Drop and Rpt 5002 Set to Drop and Rpt To RS 232 Port To RS 232 Port P P Operating Power May Be Applied Through The P Port or Through The DB 25 Connector Pins T R 5002 Set to Point to Po...

Page 3: ...ects za he SI will e ed m d m m ...

Page 4: ... 232D DCEorDTE Input Signal Voltage 5 to 30 volts per EIA RS 232D Output signal Voltage 5 to 10 volts per EIA RS 232D Optical Loss Budget 15 dB typical 62 5u Fiber Operating Wavelength 850nm Optical Connectors Industry standard ST Signal Connector Industry standard DB 25P Power Connector 2 PinCoaxial Operating Temperature Range 35 to 75 degrees C be o ng ...

Page 5: ...pin 20 20 8 ...

Page 6: ... 4 Request to Send input Connected to pin 5 5 Clear to Send output Connected to pin 4 6 Data Set Ready output Connected to pins 8 20 7 Signal Ground input output 0VDC 8 Data Carrier Detect output Connected to pins 6 20 20 Data Terminal Ready input Connected to pins 6 8 Pin Description Condition 1 Chassis Ground input output 0 VDC 2 Transmitted Data input Undetermined 3 Received Data output Pulses ...

Page 7: ......

Page 8: ...s and labor In no event shall CSI be responsible for any incidental or consequential damages or loss of profits or goodwill CSI shall not be obligated to replace or repair equipment that has been damaged by fire war acts of God or similar causes or equipment that has been serviced by unauthorized personnel altered improperly installed or abused RMA numbers and repairs can be obtained from Communic...