CSI FIBERLINK 5002 User Manual Download Page 8

2

INSTALLATION  GUIDE

Following are installation instructions

 

for the Fiberlink 5002:

Individual Transceivers

Internal Jumper Pin Setting for Drop and Repeat Operation

For “Drop and Repeat” operation, the case must be snapped open and the internal “D/R”
jumper installed.  When this is done, the unit will accept, repeat and output any data
within the loop in which it is installed.  For point-to-point operation, the “D/R” jumper
must be removed.

DB-25 Connector Considerations

The 5002 is provided with an industry standard male DB-25 connector.  For those
applications where a female connector is required, Communications Specialties offers a
male-to-female converter (part number 113024).  This device plugs directly into the
existing connector and extends the overall length of the unit by ¾ inch.

DB-25 Signal/
Power Connector

Pin 1 = Case
Pin 2= Xmit (DTE)

          Rec (DCE)
Pin 3= Rec (DTE)
          Xmit (DCE)

Pin 4= Jumped to 5
Pin 5= Jumped to 4

Pin 6= Jumped to 8/20
Pin 7= Common
Pin 8= Jumped to 6/20

Pin 9= +12 +10% VDC

No Connection to
all other pins

Optical Connectors

External Power
Connector

Install Internal Jumper

for "Drop and Repeat"
Operation

Access port for
DCE/DTE Switch

   Pin 20= Jumped to 6/8

7

WARRANTY

Communications Specialties, Inc. (CSI) warrants that for a period of three years after
purchase by the Buyer, the Fiberlink 5002 RS-232 data transceiver will be free from defects
in material and workmanship under normal use and service.  A Return Material Authoriza-
tion (RMA) number must be obtained from CSI before any equipment is returned by the
Buyer.  All material must be shipped to CSI at the expense and risk of the Buyer.

CSI’s obligation under this warranty will be limited, at its option, to either the repair or
replacement of defective units., including free materials and labor.  In no event shall CSI
be responsible for any incidental or consequential damages or loss of profits or goodwill.

CSI shall not be obligated to replace or repair equipment that has been damaged by fire,
war, acts of God, or similar causes, or equipment that has been serviced by unauthorized
personnel, altered, improperly installed or abused.

RMA numbers and repairs can be obtained from:

Communications Specialties, Inc.

55 Cabot Court

Hauppauge, NY 11788

Tel:  (631) 273-0404

Internet: www.commspecial.com

FAX: (631) 273-1638

Email: [email protected]

Customers in the Asia Pacific Region may contact Communications Specialties Pte Ltd:

Tel: +65  6391  8790

Internet: www.commspecial.com

FAX: +65  6396  0138

Email: [email protected]

Please have your serial number available when contacting us.

Summary of Contents for FIBERLINK 5002

Page 1: ...uppauge N Y 11788 USA TEL 631 273 0404 FAX 631 273 1638 INTERNET http www commspecial com EMAIL info commspecial com Communications Specialties Pte Ltd 100 Beach Road 22 09ShawTower Singapore189702 Tel 65 6391 8790 FAX 65 6396 0138 Internet www commspecial com Email csiasia commspecial com P N 102181 Rev E ...

Page 2: ...e 5002 5002 To RS 232 Port To RS 232 Port P P Operating Power May Be Applied Through The P Port or Through The DB 25 Connector Pins Typical Drop and Repeat System Configuration T R T R Fiber Optic Cable 5002 Set to Drop and Rpt 5002 Set to Drop and Rpt To RS 232 Port To RS 232 Port P P Operating Power May Be Applied Through The P Port or Through The DB 25 Connector Pins T R 5002 Set to Point to Po...

Page 3: ...ects za he SI will e ed m d m m ...

Page 4: ... 232D DCEorDTE Input Signal Voltage 5 to 30 volts per EIA RS 232D Output signal Voltage 5 to 10 volts per EIA RS 232D Optical Loss Budget 15 dB typical 62 5u Fiber Operating Wavelength 850nm Optical Connectors Industry standard ST Signal Connector Industry standard DB 25P Power Connector 2 PinCoaxial Operating Temperature Range 35 to 75 degrees C be o ng ...

Page 5: ...pin 20 20 8 ...

Page 6: ... 4 Request to Send input Connected to pin 5 5 Clear to Send output Connected to pin 4 6 Data Set Ready output Connected to pins 8 20 7 Signal Ground input output 0VDC 8 Data Carrier Detect output Connected to pins 6 20 20 Data Terminal Ready input Connected to pins 6 8 Pin Description Condition 1 Chassis Ground input output 0 VDC 2 Transmitted Data input Undetermined 3 Received Data output Pulses ...

Page 7: ......

Page 8: ...s and labor In no event shall CSI be responsible for any incidental or consequential damages or loss of profits or goodwill CSI shall not be obligated to replace or repair equipment that has been damaged by fire war acts of God or similar causes or equipment that has been serviced by unauthorized personnel altered improperly installed or abused RMA numbers and repairs can be obtained from Communic...

Reviews: