●Trigger conditions
When the buffering mode is trigger mode, set the condition to give trigger.
When the external trigger input (TRG), or the timing input signal (TIM*) is
ON, the judgment results of the trigger target output (calculation measure-
ment values of OUT1-3, calculation results of OUT-OUT calculation 1 and 2,
and calculation results of the shape judgment) (when changed to Go from Go,
Hi or Lo from Go, Lo from Hi, Lo, Hi or Lo, Hi), or an alarm occurrence
timing/cancellation timing can be set as the trigger condition. The default
value is "timing input ON".
(TIM*: 1, 2, 3 and 4 (OUT-OUT calculation 1), 5 (OUT-OUT calculation 2),
and 7 (Shape judgment) can be selected for the *.)
When the judgment results are set as the trigger condition, note that the set-
tings of the "judgment output upper/lower limits" and the "judgment output
upper/lower limit hysteresis" will activate.
When the alarm occurrence timing is set as the trigger condition, note that
the settings of the "number of alarm delays" will activate.
Buffering operation
stop
,
or reached number of
accumulation
Buffering operation
start
Trigger
occurred
Measurement
operation
Measurement data accumulation
Standby
At timing input ON
At trigger input ON
At HI
At LO
At HI or LO
Timing input or
trigger input
When HI to GO
When LO to GO
When HI or LO to GO
HI or LO output
GO output
HI or LO
output
Measurement
status
At alarm
occurrence
At alarm
cancellation
Alarm
Normal
Alarm
Normal
Measurement
status