Chapter 4 Description of Functions
4-138
4
Status
Description of
status
Cause
Measure-
ment
value
Judge-
ment
Alarm output
(Indicator)
ALARM
Status with
abnormal
measurement
value.
Insufficient light intensity
measurement fails.
+999.999
(*3)
Hold with
immediate
previous
value
(*4)
ON with con-
tinuous 10
samplings.
(*2)
Recovered
automatically.
Excessive light intensity
measurement fails.
Communication between
head controllers fails.
When the edge detect is
disabled in the X position
correct. (OUT1,2,3 and
shape judgment(OUT7))
When the edge detect is
disabled setting “with
tracking”in the Mask func-
tion.
BUSY
Data unfixed
Measurement is stopped.
+999.999
OFF
OFF
Laser is not emitted
(stopped).
Immediately after hold reset
RESTART
Re-measureme
nt is started
after stop of
measurement.
Setting conditions are sent
during measurement.
Detected light intensity
image is acquired.
ERROR
Communica-
tion with USB
is disabled.
Non-conforming command
Normal
Normal
Normal
Communication error
Device error
*1 Alarm output at the time of head disconnection is output to the alarm terminal of OUT1
for disconnection of head A and OUT2 for disconnection of head B.
*2 Alarm due to abnormal measurement value on the head is output to the corresponding
alarm terminal according to the head selection set for OUT1 to OUT3.
The number of continuous sampling until alarm can be changed. Refer to "4 -4-9 Com-
mon Settings" → "Number of measurement value alarm output delays".
*3 In hold measurement, the value immediately before is displayed.
*4 Judgement (high output ON) according to the measurement value can be made.
*5 The measurement and judgment process by the trigger input just before will continue, and
the measurement and judgment process by a new trigger input will not be accepted.
*6 For details, refer to "4-4-7 Common Settings", "Continuous measurement trigger signal
source", and "External synchronous".
4-6-2
When Alarm Continues
If abnormal measurement value status (alarm) occurs, the alarm is determined
when it occurs continuously for 10 sampling cycles. When the alarm is d e-
termined, the alarm indicator lights and the alarm output is ON.
If the alarm occurs less than 10 sampling cycles, the measurement value is
"+999.9999". The judgment result immediately befor e is held and the alarm
output is OFF.