Chapter 4 Description of Functions
4-81
4
No.
Item
Contents
(3)
Calc target (OUT-OUT calc1)
A maximum of 4 values can be set among
the ±OUT1-3 and ±OUT-OUT calc1, to
create the calculation formula.
val1
The calculation result is output synchro-
nized with the OUT selected in val1.
Calc target (OUT-OUT calc2)
A maximum of 4 values can be set among
the ±OUT1-3 and ±OUT-OUT calc1, to
create the calculation formula.
val1
The calculation result is output synchro-
nized with the OUT selected in val1.
(4)
Judgment threshold
The Hi/Go/Lo judgment can be performed
for the set calculation measurement value.
For details, refer to the "OUT Setting" -
"High judg. val.", "Lo judg. val." and "Hys.
Width".
High judg. val
Specifies the inspection judgment threshold
on the +tolerance side. When the measure-
ment value is larger than this value, the
judgment result is "Hi".
Lo judg. val
Specifies the inspection judgment threshold
on the -tolerance side. When the measure-
ment value is smaller than this value, the
judgment result is "Lo".
Hys. Width
This is used when offsetting the calculation
measurement value. When the value is set to
zero, it will become the offset value.
(5)
Offset value
This is used when offsetting the calculation
measurement value. When the value is set to
zero, it will become the offset value.